The short answer
Every new bedroom in a Washington basement needs an emergency escape and rescue opening. Under section R310 of the state residential code, which Seattle enforces with the state's amendments and none of its own, the window or door must give at least 5.7 square feet of clear opening (5 square feet at grade), at least 24 inches high and 20 inches wide, with the bottom no more than 44 inches above the floor. A well below grade must be at least 9 square feet and 36 inches each way.
Key points
- 01Each new sleeping room in a basement needs its own escape opening; a family room, office or gym in an existing basement does not.
- 02The opening must give 5.7 square feet of clear area and be at least 24 inches high and 20 inches wide, with its bottom no more than 44 inches above the floor.
- 03A well below grade needs 9 square feet of area and 36 inches each way, plus a fixed ladder or steps once it is deeper than 44 inches.
- 04In an existing basement, an existing operable window with 4 square feet of clear opening, 22 inches high and 20 inches wide, can be accepted; a newly cut opening cannot use that allowance.
In this article (7 sections)
- 01When does a basement bedroom need an egress window?
- 02What size does a basement egress window have to be?
- 03What does a basement window well need?
- 04Where can a basement escape window open to?
- 05Can an existing basement window count as the escape opening?
- 06What permit does a new basement egress window take in Seattle?
- 07What else does a legal basement bedroom need?
When does a basement bedroom need an egress window?
Whenever a new sleeping room is created. Section R310.1 of the residential code says basements, habitable attics and every sleeping room need at least one operable emergency escape and rescue opening, and that a basement with sleeping rooms needs one in each of them. For an existing basement, section R310.6 (as Seattle's code numbers it) narrows this: new sleeping rooms created in an existing basement need the opening, and other alterations or repairs of an existing basement do not.
So a basement family room, office or gym can go without one, and a basement bedroom cannot. A room without an escape opening is not a legal sleeping room and should not be rented or listed as one.
The exceptions
- Storm shelters, and basements used only to house mechanical equipment with no more than 200 square feet of floor area.
- A house with an automatic sprinkler system installed under section P2904, where the basement has either one code-compliant means of egress plus one escape opening, or two code-compliant means of egress.
- Additions follow their own rule: each new sleeping room needs an opening, and a new basement needs one unless it has a bedroom with an opening or connects to an existing basement that has one (section R310.5).
The rules are statewide. Washington's building code, which includes the International Residential Code with the state's amendments, is in effect in every county and city (RCW 19.27.031); the current edition took effect on March 15, 2024, with the state's R310 amendments in WAC 51-51-03100. SDCI says Seattle's 2024 codes will take effect no sooner than May 2027. Other cities may adopt local amendments.
What size does a basement egress window have to be?
The numbers are minimums for the clear opening, the space a person passes through when the window is opened the normal way, not the size of the frame.
- Net clear opening, or 5 sq ft for a grade-floor opening
- 5.7 sq ft
- Net clear opening, or 5 sq ft for a grade-floor opening
- Minimum clear height
- 24 in
- Minimum clear height
- Minimum clear width
- 20 in
- Minimum clear width
- Highest the bottom of the opening may be above the floor
- 44 in
- Highest the bottom of the opening may be above the floor
| Rule | Requirement | Section |
|---|---|---|
| Clear opening area | At least 5.7 sq ft. At least 5 sq ft for a grade-floor opening, one whose sill is no more than 44 in above or below the ground outside. | R310.2.1; chapter 2 definitions |
| Clear height | At least 24 in | R310.2.2 |
| Clear width | At least 20 in, from normal operation of the window or door | R310.2.2 |
| Sill height | Bottom of the clear opening no more than 44 in above the floor | R310.2.3 |
| Operation | Opens from inside without keys, tools or special knowledge. Window opening control devices meeting ASTM F2090 are allowed, no more than 70 in above the floor. | R310.1.1 |
| Doors | A door used as the escape opening must be side-hinged or sliding. | R310.3 |
| Bars, grilles and covers | Must leave the required clear opening and release from inside without a key, a tool or more force than opening the window takes. | R310.4.4 |
Read in the 2021 Seattle Residential Code, chapter 3, which prints Washington's amendments to section R310. The inspector applies the code to your window; this table is a summary.
The arithmetic
The area and both dimensions have to be met at once. 5.7 square feet is 820.8 square inches, so an opening exactly 24 inches high needs about 34.2 inches of clear width, and one exactly 20 inches wide needs about 41 inches of clear height. An opening at the 24 by 20 inch minimums gives only 480 square inches, about 3.3 square feet, and fails.
A casement swings its whole sash out, while a slider or a hung window opens only one of its two sashes and needs a larger frame for the same clear opening. Ask for the net clear opening of the exact model and size.
What does a basement window well need?
A well, which the code calls an area well, is required wherever the bottom of the escape opening is below the ground outside (section R310.4).
| Rule | Requirement | Section |
|---|---|---|
| Size | At least 9 sq ft of horizontal area, projecting at least 36 in from the wall and at least 36 in wide | R310.4.1 |
| Room to open | The well must let the window or door open fully | R310.4.1 |
| Ladder or steps | Required, permanently fixed, when the well is deeper than 44 in. The open window may not block them. | R310.4.2 |
| Ladder rungs | At least 12 in inside width, projecting at least 3 in from the wall, no more than 18 in apart vertically for the full depth | R310.4.2.1 |
| Steps | At least 12 in wide, treads at least 5 in deep, risers no more than 18 in | R310.4.2.2 |
| Encroachment | The ladder or steps may take up to 6 in of the required well dimensions | R310.4.1, exception |
| Drainage | Connected to the foundation drainage system, unless the house sits on well-drained Group I soils | R310.4.3 |
| Covers | Removable or releasable from inside without a key, a tool or extra force, leaving the required opening | R310.4.4 |
Drainage is the line that matters most in Seattle's wet season, since a well with no drain collects rain right against the window. The dry basement guide covers the foundation drain the well ties into.
Where can a basement escape window open to?
To the outside, with a way to the street. Section R310.1, as amended by Washington, says the opening must open directly to a public way, or to a yard or court with an unobstructed path at least 36 inches wide that leads to a public way.
- Gates on that path are allowed if they open without keys, tools or special knowledge.
- A window well with a removable cover that meets section R310.4.4 does not count as an obstruction.
- Under a deck, porch or cantilever, the opening must open fully and have a clear path at least 36 inches high and 36 inches wide, and no more than 60 inches long, to a yard or court. The path is measured from the outside face of the glass, or from the far wall of the window well.
Look outside before choosing the room. The escape window often decides the floor plan, because the bedroom has to sit on a wall where a well clears the gas meter, the side sewer, the property line and the path to the street.
Can an existing basement window count as the escape opening?
Sometimes. For a new bedroom in an existing basement, Seattle's code accepts an operable window that meets section R310.6.1 (the exception still cites its old number, 310.7.1). That section sets lower numbers for existing windows: a net clear opening of at least 4 square feet, at least 22 inches high and 20 inches wide. A replacement window also qualifies if it meets those numbers and is the manufacturer's largest standard size that fits the existing frame or rough opening, in the same operating style or one that opens at least as wide.
Replacing an old window that does not serve a new bedroom is simpler still: Seattle's existing-buildings chapter exempts the replacement from the size rules if it is the largest standard size that fits the opening, in the same style or one that opens wider, and is not part of a change of use (section R4402.5.4). It still has to meet the energy code.
What permit does a new basement egress window take in Seattle?
A building permit, every time. SDCI says a permit is needed for any change to the building envelope, however small the project, and cutting a new opening in a foundation wall is one. A basement bedroom with no other structural change fits the subject-to-field-inspection (STFI) permit, a quicker permit the city typically processes within a few working days and the inspector checks on site. Three things can push it toward engineering or full plan review:
- Structure. SDCI Tip 316 says that when you add a window or door in an exterior wall you must show the structure still resists wind and earthquake loads, and the city may ask for an engineer's stamped plans.
- Digging near the lot line. Excavation deeper than 4 feet near a property line, or 3 feet next to a right-of-way, falls off the STFI route unless it can be contained on the site with cuts at a 45-degree slope.
- Critical areas. Exterior work on a lot with a steep slope or another environmentally critical area needs SDCI staff approval to stay on STFI.
The new window must also meet the Seattle Energy Code's prescriptive requirements, which cap the U-factor of windows at 0.30 (Table R402.1.3). The basement permit guide covers the rest of the permit for the room.
- 01
Pick the wall
One where the well clears utilities and the lot line, with a 36-inch route to the street or alley.
- 02
Check the structure
Size the header over the opening and decide whether the city will want an engineer's stamp.
- 03
Get the permit
SDCI says work that needs a permit may not start until the permit is issued.
- 04
Excavate, cut and set
Dig the well, saw-cut the wall, frame the opening, set the window, the well, any ladder and the drain.
- 05
Inspect
The inspector checks the opening, the well and the rest of the bedroom.
What else does a legal basement bedroom need?
The window is one of several rules that make a basement room a bedroom under the 2021 Seattle Residential Code:
- A ceiling of at least 6 feet 8 inches, with beams and ducts allowed down to 6 feet 4 inches (section R4404.6).
- At least 70 square feet of floor and 7 feet in every direction (section R304).
- Smoke alarms throughout the house to the new-home standard, including one in the bedroom, and carbon monoxide alarms outside each sleeping area and on each level (sections R314 and R315).
- Heat able to hold 68 degrees F without portable heaters (section R303.10).
Giant Builders measures the ceiling and finds the wall where an escape window can go at the free in-home estimate, then prepares and files the permits. The basement finishing page and the basement cost guide cover the rest of the project.
Questions people also ask
01Does a basement office or gym need an egress window?
02Can a door be the escape opening?
03Do the rules differ in Bellevue, Kirkland or Redmond?
04Can a window well have a cover?
Sources
- 012021 Seattle Residential Code, chapter 3: sections R303, R304, R310, R314 and R315 (read Nov 26, 2026)
- 022021 Seattle Residential Code, chapter 2: definitions (grade floor emergency escape and rescue opening) (read Nov 26, 2026)
- 032021 Seattle Residential Code, chapter 44: existing buildings (sections R4402.5.4 and R4404.6) (read Nov 26, 2026)
- 04WAC 51-51-03100: Washington amendments to IRC section R310, emergency escape and rescue openings (effective March 15, 2024) (read Nov 26, 2026)
- 05RCW 19.27.031: the state building code in effect in all counties and cities (read Nov 26, 2026)
- 06Seattle SDCI Tip 316: Subject-to-field-inspection permits (updated Oct. 29, 2026) (read Nov 26, 2026)
- 07Seattle SDCI: Do you need a permit? (read Nov 26, 2026)
- 082021 Seattle Energy Code, residential provisions, chapter 4: Table R402.1.3 (read Nov 26, 2026)
- 09Seattle SDCI: Residential code (Seattle has adopted the 2021 IRC with local amendments) (read Nov 26, 2026)
- 10Seattle SDCI: Seattle code adoption, 2024 codes no sooner than May 2027 (read Nov 26, 2026)
Rules, rates and programs change. This article was checked against the sources above on the dates shown. It is general information for homeowners, not legal, tax or engineering advice for a specific property.