Permit guide · Seattle
Do you need a permit to finish a basement in Seattle?
Yes, and the permit is the easy part. What decides a basement project is the code behind it: how tall the ceiling is, whether a bedroom has a way out, and whether the space becomes a second home. Each rule here is quoted from the code section it comes from.
By Giant Builders SeattleUpdated Rules checked against city sources in November 2026

- WA contractor license
- GIANTBS782RZ
- UBI
- 604991679
- Permits
- Prepared and filed by us
- Workmanship warranty
- 5 years
- Estimate
- Free, in your home, in writing
The short answer
Yes. Turning a basement into living space needs a construction permit from the city, usually the quick field-inspection kind, plus electrical and plumbing permits. The code asks for a ceiling of at least 6 feet 8 inches in an existing house, and every new bedroom needs an emergency escape window or door.
- Ceiling height for living space created in an existing basement
- 6 ft 8 in
- Clear opening of a bedroom's escape window
- 5.7 sq ft
- Smallest window well, 36 inches each way
- 9 sq ft
- The city's screening time for a field-inspection permit
- A few days
The permit route
Which permit each kind of basement project needs
| Project | Building permit | Other permits |
|---|---|---|
| Refinishing a basement that is already living space: paint, new finishes over the existing walls | None | Electrical or plumbing, only if those are changed |
| Finishing an unfinished basement as a family room, office or gym | Construction permit, field-inspection route | Electrical |
| Adding a bedroom | Field-inspection route. The plans must show the escape opening; cutting a new window into the foundation wall can bring a request for engineering | Electrical |
| Adding a bathroom | Field-inspection route | Plumbing from Public Health, electrical |
| Removing posts or changing a beam | Field-inspection route within the city's span limits, or with an engineer's stamped plans | As needed |
| Lowering the basement floor | Full plan review. The city excludes this work from the field-inspection permit | As needed |
| Creating a basement apartment | Full plan review. Creating a dwelling unit is excluded from the field-inspection permit | Electrical, plumbing, and King County's sewer capacity charge |
Why there is no way around the permit
Seattle exempts minor alterations worth $6,000 or less in six months, and new finishes over existing walls. Framing, insulating, wiring and drywalling a bare basement is neither. The city’s own page on addition and alteration permits gives “converting a basement to living space” as its first example of a project that needs one.
The good news is the route. A basement finish with no structural change is the kind of interior alteration the subject-to-field-inspection permit was made for: the city screens it in a few days and the inspector reviews the code on site.
The code
What the Seattle Residential Code asks of a finished basement
| Rule | What the code asks for | Section |
|---|---|---|
| Ceiling height | At least 6 ft 8 in where habitable space is created in the basement of an existing building. 6 ft 4 in in bathrooms, toilet rooms and laundry rooms. | SRC R4404.6 |
| Beams and ducts | Beams, girders, ducts and other obstructions may come down to 6 ft 4 in above the finished floor. | SRC R4404.6, exception 2 |
| Escape opening | Each new sleeping room created in an existing basement needs an emergency escape and rescue opening. Other alterations of an existing basement do not require one. | SRC R310.6 |
| Size of the opening | 5.7 sq ft of net clear opening (5 sq ft at the grade floor), at least 24 in high and 20 in wide, bottom of the opening no more than 44 in above the floor. It must open from inside without a key or a tool. | SRC R310.1.1 and R310.2 |
| Window well | Where the opening is below grade: a well of at least 9 sq ft, projecting and measuring at least 36 in, a fixed ladder or steps if it is deeper than 44 in, and drainage to the foundation drain. | SRC R310.4 |
| Existing windows | An existing operable window can serve as the escape opening if it gives at least 4 sq ft of clear opening, 22 in high and 20 in wide. | SRC R310.6 and R310.6.1 |
| Path outside | The opening must lead to a public way, or to a yard with an unobstructed path at least 36 in wide to one. | SRC R310.1 |
| Room size | A habitable room has at least 70 sq ft of floor and is at least 7 ft in each direction. | SRC R304 |
| Light and air | Glazing equal to 8% of the floor area, or artificial light in its place. Space converted to living space must have ventilation. | SRC R303.1 and R4404.5 |
| Smoke and CO alarms | Smoke alarms as in a new home when permitted alterations are made or a bedroom is added. Carbon monoxide alarms outside each sleeping area and on each level. | SRC R314.2.2 and R315.2 |
| Stairs | Existing stairs that are not altered may keep their width and headroom. A new stair needs 36 in of width, risers of 7 3/4 in at most, treads of 10 in at least and 6 ft 8 in of headroom. | SRC R4404.7, SDCI Tip 303A |
How to measure your ceiling
Measure from the slab to the underside of the floor joists above, then take off what the finish adds: about half an inch to an inch for flooring and five eighths of an inch for a drywall ceiling. What is left has to be 6 feet 8 inches or more. Then find the lowest thing in the room, usually a beam or the main duct, and check that it clears 6 feet 4 inches after the finish.
If the room passes but a duct does not, the duct can often be moved or reshaped. If the whole ceiling is short, the choices are to lower the floor, which is structural work beside the footings and needs full plan review, or to use the space for storage and laundry. An older rule, Director’s Rule 23-2008, allowed 6 feet 4 inches for dwelling space in buildings that existed before October 17, 1979, under conditions. Ask the city whether it still applies before deciding.
Where the bedroom can go
The escape opening decides the floor plan. The bedroom has to sit on a wall where a window of the required size can open to the outside with a clear path to the street or the alley, and where a well will not collide with a gas meter, a side sewer or the property line. We locate that wall first and draw the rest of the basement around it.
Fees
What basement permits cost in Seattle in 2026
| Value of the work | Field-inspection permit | Permit with full plan review |
|---|---|---|
| $50,000 | $1,611.86 | $2,302.65 |
| $95,000 | $2,574.71 | $3,678.15 |
| $160,000 | $3,361.16 | $4,801.65 |
The other permits
- Electrical (SDCI): $55.48 plus $26.28 for each new circuit up to 25 amps, and $146 or $292 if the service has to be replaced, plus 5%.
- Plumbing (Public Health): $137 plus $27 per fixture, for a bathroom, a bar sink or a laundry.
- For an apartment only: King County’s sewer capacity charge, $46.01 a month for 15 years, $8,281.80 over the full term.
The field-inspection permit is valid for 18 months, and work that needs it may not start until it is issued.
A worked example
The permits on a basement apartment, added up
Worked example, not a real job
Example: a basement finished as a one-bedroom rental apartment
A typical basement apartment valued at $160,000, inside the usual Seattle range of $120,000 to $200,000, in a basement that is dry and has 6 feet 10 inches of height. Creating a dwelling unit means full plan review. Every fee is computed from the 2026 schedules.
| Line | How it is worked out | Amount |
|---|---|---|
| Construction contract | The example figure the fees are based on. | $160,000 |
| Sales tax | 10.55% of the contract price (Seattle, October to December 2026). | $16,880 |
| Building permit and plan review (SDCI) | Permit fee $2,286.50, plan review fee $2,286.50, technology fee $228.65. | $4,801.65 |
| Electrical permit (SDCI) | $55.48 administrative fee, 8 circuits up to 25 amps, one range circuit, plus 5%. | $325 |
| Plumbing permit (Public Health) | $137 plus $27 for each of 6 fixtures. | $299 |
| Total with tax and permits | $182,305.65 | |
Get the permit list for your basement
The permit navigator asks what you are building and where you live, and returns the permits that apply, for Seattle and for the cities around it.
Questions
Basement permit questions, answered
01Do I need a permit to finish my basement in Seattle?
Yes. The city lists converting a basement to living space as a project that needs a construction permit for an addition or alteration, and says simple ones may qualify for the quicker subject-to-field-inspection permit. New wiring needs an electrical permit from the city and a bathroom needs a plumbing permit from Public Health Seattle & King County. Only refinishing a basement that is already living space, with paint and new finishes over the existing walls, needs no building permit.
02Is my basement ceiling high enough?
In an existing house, Seattle Residential Code section R4404.6 asks for at least 6 feet 8 inches where habitable space is created in a basement, and 6 feet 4 inches in bathrooms, toilet rooms and laundry rooms. Beams, girders, ducts and other obstructions may hang down to 6 feet 4 inches. The 7 foot figure many guides quote is the rule for new construction. If your basement is lower, the floor has to be lowered, and that takes the project off the quick permit.
03Do I need an egress window for a basement bedroom?
Yes. The code says new sleeping rooms created in an existing basement must have an emergency escape and rescue opening, a window or a door, in each sleeping room. Other alterations of an existing basement do not trigger the requirement, so a family room or an office does not need one. A house with a fire sprinkler system has an exception when the basement has a second way out.
04What size does a basement egress window have to be in Seattle?
The clear opening must be at least 5.7 square feet, or 5 square feet at the grade floor, at least 24 inches high and at least 20 inches wide, with the bottom of the opening no more than 44 inches above the floor. If the opening is below ground it needs an area well of at least 9 square feet, 36 inches out from the wall and 36 inches wide, with a fixed ladder or steps when the well is deeper than 44 inches. In an existing basement, an existing operable window can be accepted if it gives 4 square feet of clear opening, 22 inches high and 20 inches wide.
05Can I turn my basement into a rental unit?
Yes. A basement apartment is an attached accessory dwelling unit. Seattle allows up to two accessory units on a lot, requires no parking for them and has no rule that the owner live on the property. The unit must be created by permit to be legal, the permit goes through full plan review, and King County bills a sewer capacity charge of $46.01 a month for 15 years for the new unit.
06Do I have to rebuild my old basement stairs?
Not if you leave them alone. The code's chapter on existing buildings says existing stairs that are not being altered may keep their current width and headroom, and that an existing stairway need not meet the tread and riser rules where the space does not allow it. Stairs that are rebuilt must have a handrail and guard, and the stairway in the work area needs light.
07How long does a basement permit take in Seattle?
The city says screening a subject-to-field-inspection permit takes a few days. A basement apartment, or a project that lowers the floor, needs full plan review: the city tries to finish its first review of a simple application in two to three weeks and of a complex one in eight, and corrections add time. The permit is valid for 18 months.
08How much does a basement finishing permit cost in Seattle?
The building permit fee follows the value of the work. In 2026 a field-inspection permit comes to $1,611.86 for $50,000 of work and $2,574.71 for $95,000, technology fee included. Full plan review for a $160,000 apartment comes to $4,801.65. Add an electrical permit, priced by the circuit, and a plumbing permit at $137 plus $27 per fixture.
Free estimate
Find out what your basement can become
We measure the ceiling, find the wall where a bedroom window can go, check for water, and tell you which permit route your project takes. Then we prepare and file the permits.
Washington general contractor GIANTBS782RZ, registered with the Department of Labor & Industries. The record is public.
Keep reading
- Basement finishingWhat is included and how a basement project runs.
- Basement finishing cost in SeattleCost by scope and per square foot, with tax and permits.
- Seattle ADU and DADU rulesIf the basement is going to be a second home.
- Bathroom remodel permits in SeattleThe plumbing permit and the bathroom code rules.
Sources
- 01Seattle SDCI: Construction permit, addition or alteration (read Nov 18, 2026)
- 02Seattle SDCI: Do you need a permit? (read Nov 18, 2026)
- 032021 Seattle Residential Code, chapter 1: section R105.2, work exempt from permit (read Nov 18, 2026)
- 042021 Seattle Residential Code, chapter 3: sections R303 to R315 (light, room size, ceiling height, escape openings, alarms) (read Nov 18, 2026)
- 052021 Seattle Residential Code, chapter 44: existing buildings (section R4404.6, ceiling height) (read Nov 18, 2026)
- 06Seattle Director's Rule 23-2008: 6 foot 4 inch ceiling height in older dwellings (read Nov 18, 2026)
- 07Seattle SDCI Tip 316: Subject-to-field-inspection permits (updated Oct. 29, 2026) (read Nov 18, 2026)
- 08Seattle SDCI Tip 303A: Common Seattle Residential Code requirements (dated Dec. 8, 2021) (read Nov 18, 2026)
- 09Seattle SDCI: Construction permit, subject to field inspection (read Nov 18, 2026)
- 10Seattle SDCI: 2026 Fee Subtitle (effective Jan. 1, 2026) (read Nov 18, 2026)
- 11Seattle SDCI: Electrical permit (read Nov 18, 2026)
- 12Public Health Seattle & King County: plumbing and gas piping permits (read Nov 18, 2026)
- 13Public Health Seattle & King County: plumbing and gas piping fees (effective Jan. 1, 2026) (read Nov 18, 2026)
- 14Seattle SDCI: Accessory dwelling units (read Nov 18, 2026)
- 15Seattle Ordinance 127376: Neighborhood Residential update, amends SMC 23.42.022 (passed Dec. 16, 2025; in effect Jan. 21, 2026) (read Nov 18, 2026)
- 16King County: sewage treatment capacity charge, 2026 rates (read Nov 18, 2026)
- 17Washington Dept. of Revenue: local sales tax rates, October to December 2026 (read Nov 18, 2026)